Australian standards compliance for automatic doors

Australian standards compliance for automatic doors

blog2_800x460

Compliance for Automatic Pedestrian Doors

Australia has a number of codes and compliance laws that are regulated by federal agencies in order to ensure that pedestrian doorways are safely accessible to everyone.

Below are some of the compliance laws and codes that every business must adhere to when installing pedestrian doors:

  • AS 5007 – 2007 – Powered doors for pedestrian access and egress
  • AS 1428.1 – 2009 – Design for access & mobility
  • The Building Code of Australia (BCA)

AS 5007-2007 is an outlined code for compliance laws that regulate the design and testing of pedestrian door parts, doorways design, drive units, and leaves associated with the use of “powered pedestrian doors” in a business.

These set of guidelines also mandate how pedestrian doors should be installed in every commercial business before commissioning of the doorway.

These rules are set in place to make sure that public doorways are safe for everyone to use. It is important to note that part of this standard states that it is up to the building owner to ensure that the automatic doors are safe and in order to do this, powered pedestrian doors should be inspected and maintained no less than every 4 months.

Some of the requirements that are listed in the above standards and codes include but are not limited to the following:

  • Switches and controls on an accessible path of travel for an automatic door should not be less than 900mm or more than 1100mm from finished floor level
  • Door signage should be at 1200 – 1600mm from finished floor level on automatic sliding doors
  • The minimum clear opening of a doorway shall not be less than 850mm

Here at AADS, we pride ourselves on providing safe, reliable, and compliant door solutions for any business. All of our installations are tested to ensure that they meet the requirements outlined in the Australian Compliance Standards. We are the top provider for all automatic door solutions in the Australian metro regions.

Contact AADS today in order to discuss the details of your next project, we can help you through the entire process to ensure that your design, installation, and safety compliance all meet the level of quality as expected by not only us at AADS but also you the business owner.

(Revised Above)

Australian standards compliance for automatic doors

The “Australia Standard AS5007-2007” is a set of ordinances issued by Australia requiring the testing and certification of any parts, design, drive units, and leaves associated with the use of “powered pedestrian doors” in a business. Every set of automatic doors must undergo a strict testing process to ensure the safety of the public while also making sure that the door’s systems are functioning properly as they should.

While this compliance is currently in effect, Australia lacks the resources necessary to fully test each manufactured powered door that is currently installed in various buildings around the city. This leaves testing procedures and safety requirements up to the manufacturers.

Luckily given the nature of the business many manufacturers already comply with several “Australia Standard AS5007-2007” requirements through production and development.

We at AADS pride ourselves on providing safe, reliable, and energy efficient door solutions for business purpose. At AADS we do not install any automatic doors that fail to meet the requirements outlined in the “Australia Standard AS5007-2007” which makes us one of the top providers in Australia for any of your automatic doors needs.

Some of the requirements that are listed in the “Australia Standard AS5007-2007” follow below

  • The unobstructed height throughout must be not less than 2 m, except the unobstructed height of any doorway may be reduced to not less than 1980 mm.
  • The unobstructed width of each exit or path of travel to an exit, except for doorways, must be not less than.
  • In an open spectator stand which accommodates more than 2000 persons, the aggregate unobstructed width, except for doorways, must be increased to 17 m plus a width (in metres) equal to the number in excess of 2000 divided by 600

These are just some of the requirements that are stated in the “Australia Standard AS5007-2007”

Contact AADS to discuss the details of your project and we can help you in the process of automatic door installation for your new business.

 

 

 

 

 

Leave a Reply

Your email address will not be published. Required fields are marked *